399 research outputs found

    Noise Thermal Impedance of a Diffusive Wire

    Full text link
    The current noise density S of a conductor in equilibrium, the Johnson noise, is determined by its temperature T: S=4kTG with G the conductance. The sample's noise temperature Tn=S/(4kG) generalizes T for a system out of equilibrium. We introduce the "noise thermal impedance" of a sample as the amplitude of the oscillation of Tn when heated by an oscillating power. For a macroscopic sample, it is the usual thermal impedance. We show for a diffusive wire how this (complex) frequency-dependent quantity gives access to the electron-phonon interaction time in a long wire and to the diffusion time in a shorter one, and how its real part may also give access to the electron-electron inelastic time. These times are not simply accessible from the frequency dependence of S itself.Comment: 4 pages, 2 figure

    Measurement of non-Gaussian shot noise: influence of the environment

    Full text link
    We present the first measurements of the third moment of the voltage fluctuations in a conductor. This technique can provide new and complementary information on the electronic transport in conducting systems. The measurement was performed on non-superconducting tunnel junctions as a function of voltage bias, for various temperatures and bandwidths up to 1GHz. The data demonstrate the significant effect of the electromagnetic environment of the sample.Comment: 13 pages, for the SPIE International Symposium on Fluctuations and Noise, Maspalomas, Gran Canaria, Spain (May 2004

    Environmental effects in the third moment of voltage fluctuations in a tunnel junction

    Full text link
    We present the first measurements of the third moment of the voltage fluctuations in a conductor. This technique can provide new and complementary information on the electronic transport in conducting systems. The measurement was performed on non-superconducting tunnel junctions as a function of voltage bias, for various temperatures and bandwidths up to 1GHz. The data demonstrate the significant effect of the electromagnetic environment of the sample.Comment: Major revision. More experimental results. New interpretation. 4 pages, 3 figure

    Bolometric and non-bolometric radio frequency detection in a metallic single-walled carbon nanotube

    Full text link
    We characterize radio frequency detection in a high-quality metallic single-walled carbon nanotube. At a bath temperature of 77 K, only bolometric (thermal) detection is seen. At a bath temperature of 4.2 K and low bias current, the response is due instead to the electrical nonlinearity of the non-ohmic contacts. At higher bias currents, the contacts recover ohmic behavior and the observed response agrees well with the calculated bolometric responsivity. The bolometric response is expected to operate at terahertz frequencies, and we discuss some of the practical issues associated with developing high frequency detectors based on carbon nanotubes.Comment: 11 pages (double-spaced), 3 figure

    Energy resolution of terahertz single-photon-sensitive bolometric detectors

    Get PDF
    We report measurements of the energy resolution of ultra-sensitive superconducting bolometric detectors. The device is a superconducting titanium nanobridge with niobium contacts. A fast microwave pulse is used to simulate a single higher-frequency photon, where the absorbed energy of the pulse is equal to the photon energy. This technique allows precise calibration of the input coupling and avoids problems with unwanted background photons. Present devices have an intrinsic full-width at half-maximum energy resolution of approximately 23 terahertz, near the predicted value due to intrinsic thermal fluctuation noise.Comment: 11 pages (double-spaced), 5 figures; minor revision
    • …
    corecore